SIEMENS OLM G12 PDF

Nov 26 2018
admin

Description and Operating Instructions. SIMATIC NET PROFIBUS. Optical Link Modules. OLM/P OLM/P OLM/G OLM/G OLM/GEEC. OLM/G SIMATIC NET PROFIBUS Optical Link Module OLM / P11 V OLM / P12 V OLM / P22 V OLM / P11 V OLM / G12 V OLM / G22 V OLM. 30 Oct PROFIBUS OLM/G12 V Optical Link Module with 1 RS and 2 glass FOC interfaces (4 BFOC sockets) for standard Distances up to.

Author: Akigis Dak
Country: Hungary
Language: English (Spanish)
Genre: Politics
Published (Last): 17 June 2012
Pages: 392
PDF File Size: 2.96 Mb
ePub File Size: 17.74 Mb
ISBN: 778-1-51334-757-9
Downloads: 79401
Price: Free* [*Free Regsitration Required]
Uploader: Fauk

Chemical Resistive Pressure Sensor.

Redundancy Monitoring Mains buffering. Monitoring and Control Devices.

OLM optical link module

I checked the opm connectivity and it seems ok. Switched Mode Power Supplies. Do you have a question? Optical sensors Special sensors Stainless steel sensors Forked sensors.

Can you tell me what status actually the System LED indicates? Delivery times to other countries and information how to calculate see here. But the IOs are not detected in hardware config.

FO Communication using OLM G12 – Entries – Forum – Industry Support – Siemens

Portable Fixed – Water. See the attachment for basic information.

Related Files:  BUILDING WITH HEMP STEVE ALLIN PDF

The distance between two OLMs in the redundant ring is only limited by the optical range of the modules RS interface with segment capability Sub-D female connector Unrestricted multimaster operation: Single Phase siejens and voltage monitors Three phase monitoring Insulation monitoring Thermistor motor protection Timer Relays. Currently I am trying for one of my RIO panels.

Thanks in advance Attachment doc Sjemens of module status through floating signaling contact Checking the fiber optic cable route quality on LEDs Checking the fiber optic cable route quality Measurement output y12 optical receiver for logging and plausibility checking of the fiber optic path attenuation with a voltmeter High cascading depth: Command panel Support arm systems They are offered preassembled with four BFOC plugs and an insertion tool.

Expanded segmentation functions for localization of faults to fiber optic and RS segments Fast localization of faults: You need to check the fiber optic wiring. Ex enclosures Stainless steel, empty enclosure with screw fastened cover Ex enclosures Stainless steel Ex enclosures Ol. I have set the baud rate as Why not ask one of our experts?

Related Files:  TOSHIBA 40E220U MANUAL EPUB DOWNLOAD

OLM optical link module – Industry Mall – Siemens WW

Please cross-check your requirements always with official Siemens documentation. GauravJoshi Hi Mark, I did the required settings as advised. Hello Gaurav; You should find the information you need in section 5. Please don’t send support requests as PM. Installation fitting type PVC-U metric glue on saddle. Small and Compact enclosures Enclosure systems Console systems Command panel and Support arm systems.

An electrical bus segment must always be terminated at both ends. Find the network setup in the attachment.

Also “Experts” are pleased about feedback. Pushbutton Units and Indicator Lights.

Condition Monitoring of Everything. The 24 V power supply is fed in through a terminal block and can be redundantly connected.