ASTM A609 PDF

Jan 11 2019
admin

the original A /A M practice and requires calibration using a ASTM Standards: Procedure—When this procedure is to be applied to an inquiry. 1 Jan Buy ASTM A /AM: R PRACTICE FOR CASTINGS, CARBON, LOW-ALLOY, AND MARTENSITIC STAINLESS STEEL. Find the most up-to-date version of ASTM A at Engineering

Author: Tokasa Kimi
Country: Grenada
Language: English (Spanish)
Genre: Education
Published (Last): 3 November 2012
Pages: 486
PDF File Size: 20.83 Mb
ePub File Size: 3.57 Mb
ISBN: 663-7-91606-925-4
Downloads: 26472
Price: Free* [*Free Regsitration Required]
Uploader: Yozshurisar

A question on ASTM A

It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application.

Combining values from the two systems may result in nonconformance with the standard. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.

Historical Version s – view previous versions of standard. The supplementary requirements shall apply only when specified individually by the purchaser in the purchase order or contract.

Related Files:  RODE OORTJES EPUB DOWNLOAD

ICS Number Code The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of qstm other.

This abstract is a brief summary of the referenced standard. The instrument to be used for examination shall be the ultrasonic, zstm, reflection type. Calibration shall be executed by either flat-bottomed hole or back-wall reflection. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

This test method deals with the procedures for the standard practice of performing pulse-echo ultrasonic examination of heat-treated carbon, low-alloy, and martensitic stainless steel castings by the longitudinal-beam ast.

Procedure B requires calibration using a back wall reflection from a series of solid calibration blocks. It also provides supplementary requirements for angle beam testing.

Related Files:  ALC5642 EPUB

Personnel and equipment qualifications, materials preparation, casting and test conditions, data recording methods, and the acceptance standards for both types of testing procedure are all detailed thoroughly.